About Air Sampler Apm 154
Air Sampler Apm 154
With prosperous understanding and market expertise, we are engaged in manufacturing and exporting a wide range of Air Samplers. The offered samplers are fabricated by our adept professionals using superior grade materials and modern technology. The air monitoring provides information on the quality of the processing environment during manufacturing and enables the study microbiological air quality trends. Additionally, it is checked to ensure its perfect quality. We are offering this Air Samplers at reasonable price.
Features :
- Reliable operation
- High performance
- Long functional life
-
Fine Particulate Sampler
-
PM 2.5 Sampler
-
Item Code: APM-154
Special features :
- PM10 and PM2.5 Impactors of sampler based on designs standardized by US EPA
- Two part cabinet ensures that temperature of PM 2.5 filter remains close to ambient temperature
- Diaphragm Pump with a low noise
- Lower sampling rate of 1m3/hr reduces filter choking even in areas having high FPM levels
- Critical Orifice maintains constant sampling rate of 1 m3/hour
- Sampler can run continuously 28 hrs monitoring
- Low power consumption
- Low weight essay to transport in field
- Can be measure PM10 or PM2.5 at a time
- Calibration Certificate for each instrument shall be provided with instruments
- Compact and portable.
- Weight: Approx 25 Kg.
Owing to its modular design, APM 154 can be easily paired with a gaseous sampling attachment (for monitoring SO2, NOx, NH3, Ozone etc.) as gaseous sampling requires only a few LPM of air flow. This is possible through an attachable subsidiary unit LES 411. Kindly refer to respective brochures of LES 411
Specification :
- Size Selective inlets: Omni-directional air inlet with PM 10 separation through an impactor followed by PM 2.5 separation through a WINS Impactor
- Flow Rate: Constant sampling rate of 1 m3/hr unaffected by voltage fluctuation and filter choking maintained by critical orifice system
- Sampling Time Record: 0 to 9999.99 hrs. recorded on a Time Totalizer
- Vacuum Pump: Diaphragm Pump
- Power requirement: Nominal 220 V, Single Phase, 50Hz AC mains supply. For proper operation and safety a good earth connection is mandatory
- Automatic Sampling: 24 hrs programmable timer to automatically shut off the system after pre-Control set time interval.
- Sample Volume: Dry Gas meter records the total air volume sampled
- Filter: Filter holder designed to accept any standard 47 mm diameter filter media
- Warranty: One year
Specification
| Frequency | 50 hz |
| Voltage | 220 V |
| Automation | Automatic |
| Diameter | 47 mm |
| Display | Digital |
| Material | SS |
Efficient and Reliable Air SamplingThe APM 154 Air Sampler delivers consistent, high-efficiency sampling thanks to its advanced controller and rotameter. Designed for prolonged, continuous operation, its oil-free compressor and overload protection safeguard both the device and the integrity of your results. Its low power consumption and quiet profile make it ideal for laboratory settings.
User-Friendly and Portable DesignWith a robust yet lightweight aluminium structure and compact dimensions (21 x 30 x 30 cm), the APM 154 is eminently portable. Its table-top orientation and minimal noise output cater to laboratory environments where discretion and ease of use are essential. Accessories included support quick set-up and reliable transport.
Versatile Applications and Accurate MeasurementThe Air Sampler APM 154 is engineered for accurate measurement of particulate matter and microbial contaminants. With a manual filtration sensor and a broad adjustable flow range, this device suits various monitoring needsranging from laboratory research to on-site pollution studiessupported by an analog display for intuitive operation.
FAQs of Air Sampler Apm 154:
Q: How does the Air Sampler APM 154 operate to collect air samples?
A: The APM 154 uses a manual filtration system with a 400-mesh aluminium sampling head and rotameter to adjust air flow from 1 to 10 LPM. Air is drawn through filter media, efficiently capturing particulates or microbes for analysis.
Q: What types of substances can be measured with the APM 154 Air Sampler?
A: This sampler is designed to measure airborne particulate matter and microbial contaminants, making it suitable for environmental monitoring and laboratory analyses.
Q: When is it recommended to use the APM 154 for air sampling?
A: The APM 154 is ideal for continuous monitoring during laboratory research, routine environmental quality checks, or pollution surveillance projects, especially when precise and reliable measurement is required.
Q: Where can the Air Sampler APM 154 be set up for sampling?
A: Thanks to its compact, lightweight design and tabletop orientation, the APM 154 can be conveniently placed in laboratories, research facilities, or transported to field sites across India for on-site sampling.
Q: What is the process for adjusting the air flow on the APM 154?
A: Air flow is easily adjusted using the integrated rotameter, allowing for precise control between 1 and 10 liters per minute according to your sampling requirements.
Q: How does the APM 154 benefit laboratory and field users?
A: This sampler offers high sampling efficiency, low power consumption, and quiet, stable operation. Its durability, portability, and intuitive controls make it a valuable tool for researchers and field personnel alike.